Uneven Foot Flatness on the Fan Bearing Housing Causes Binding

E43-278 · Rolling Bearing Fit Errors · Boiler Induced Draft Fan Bearing Housing ∅90, shim levelling flatness designed ≤0.05, actual 0.2 · ★★

Problem Symptom

A foot-to-foundation flatness of 0.2mm (allowable 0.05) deformed the housing by 0.1, distorting the bearing bore and raising the temperature

Root Cause

[Mechanism] The uneven feet bent the housing and distorted the bearing bore.
[Calculation] A flatness of 0.2 bent the housing by δ=0.1, so the tilted bearing bore unevenly loaded the rollers, causing binding and a temperature rise.
[Design Omission] The shims were not levelled; this design flaw caused the binding.

Correct Solution

1) Level with shims to flatness ≤0.05 to prevent bending;
2) Lap the housing feet;
3) Use secondary grouting to fix the housing;
4) Re-bore the housing bore to restore concentricity;
5) Check free movement after installation;
6) Run in and listen for abnormal noise;
7) Check the temperature rise;
8) Bring levelling into the installation procedure.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances