Loose Tie Bar Bearing Fit Tilts the Injection Moulding Platen

E43-280 · Rolling Bearing Fit Errors · Injection Moulding Machine Tie Bar Bearing Housing ∅80, designed K7 interference 0.03, actual clearance 0.15 · ★★

Problem Symptom

A clearance of 0.15mm between the bearing and the housing (allowable 0.03) tilted the platen 0.1, so the mould did not close evenly and the parts flashed

Root Cause

[Mechanism] The large clearance let the housing wobble and the platen parallelism was lost.
[Calculation] A clearance δ=0.15 tilted the platen by θ=δ/L≈0.1, so the uneven closing produced flash.
[Design Omission] No interference fit was specified; this design flaw caused the platen tilt.

Correct Solution

1) Change the housing bore to K7 interference 0.01~0.03 to prevent wobble;
2) Provide axial location for the outer ring;
3) Finish bore the housing to guarantee roundness;
4) Select a self-aligning roller bearing to compensate the difference;
5) Inspect the parallelism after installation;
6) Trial the mould to check for flash;
7) Check the temperature rise;
8) Bring the fit onto the drawing.