Insufficient Interference on Tangent Keys Causes Slipping

E43-040 · Key and Spline Fit Errors · Large Coupling Tangent Keys · ★★★

Problem Symptom

The tangent key wedge fit was loose and slipped at 2000N·m; 8 line stops per month

Root Cause

[Insufficient Wedging] The inclined faces of the two keys were not driven tight, giving a contact pressure of only 15MPa and insufficient frictional transmission.
[Slipping] The required contact pressure p=T/(μ·d·L·0.5)=2000/(0.15×100×120×0.5)=2.22MPa was easily achievable, but the clearance on the inclined faces halved the effective contact.
[Design Omission] Tangent keys should have their inclined faces lapped and driven tight to a contact pressure of ≥30MPa, and spot welded to prevent backing off.

Correct Solution

1) Lap and drive tight the tangent key inclined faces to guarantee torque transmission;
2) Require contact pressure ≥30MPa to prevent crushing;
3) Hand-fit the key and keyway to guarantee contact;
4) Spot weld the ends to prevent backing off;
5) Calibrate the torque to verify torque transmission;
6) Check contact ≥70% with blueing compound on the first piece to verify fit;
7) Check for slipping during operation to confirm reliability;
8) Bring the tangent key process into the assembly card.

Checklist

References

GB/T 1974-2003 Tangent Keys

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL