Problem Symptom

Tangent key taper 1:100 was designed but 1:200 was used; insufficient tightening caused slipping

Root Cause

[Wrong Taper] 1:100 was designed but 1:200 was used by mistake, giving a small wedge angle and weak self-locking.
[Slipping] The shallow taper left the key unable to transmit the required torque, so it slipped.
[Design Omission] Tangent keys should be 1:100 with the tightening controlled, but no taper inspection was done.

Correct Solution

1) Use a 1:100 taper on the tangent key;
2) Match the key to the keyway;
3) Control the tightening force;
4) Require contact area ≥80%;
5) Verify against T;
6) Inspect the taper on the first piece;
7) Run a torque test;
8) Replace out-of-specification keys.