E43-785 · Key and Spline Fit Error · Heavy-duty shaft flat key whose key-side compressive stress exceeds the material's allowable value under torque, plastic crushing of the key and keyway and torque-transmission failure · ★★★★
The flat key on a heavy-duty shaft is undersized in cross-section; under torque the key-side compressive stress exceeds the material's allowable compressive stress, the key and keyway contact surfaces crush plastically, clearance grows, and torque transmission fails with play.
[Mechanism] A flat key transmits torque by compression on its sides; the key-side compressive stress = 2T/(dhl). If it exceeds the allowable value, the key sides crush, the clearance grows, and the joint fails.
[Calculation] The small key cross-section pushes the compressive stress 100MPa above the allowable value, plastically crushing the key sides, cutting torque capacity, and causing play.
[Design Omission] The key cross-section / length is insufficient and the compressive stress exceeds the limit; this design flaw leads to key-side crushing.
1) Check the key cross-section and length against compressive strength;
2) Lengthen the key, use two keys, or switch to a spline if necessary;
3) Upgrade key material strength;
4) Measure the key-side stress on the first article;
5) Harden the keyway surface;
6) Guarantee the contact area;
7) Note the key specification and the strength check on the drawing;
8) Verify under heavy load.
GB/T 1095-2003 Flat keys — Cross-section dimensions for keyways