E43-794 · Key-and-Spline Fit Error · A straight-sided spline centered on the major diameter with 0.08mm clearance, too large, gives poor centering, rotational wobble and vibration of the spline pair · ★★★
A straight-sided spline uses major-diameter centering, but the internal/external major-diameter clearance of 0.08mm is too large; centering is poor, the spline pair wobbles in rotation, radial vibration rises, and tooth-side wear accelerates.
[Mechanism] Major-diameter centering relies on the internal/external major-diameter fit; excessive major-diameter clearance gives poor centering, wobble and vibration, and eccentric tooth-side wear.
[Calculation] A 0.08mm major-diameter clearance gives 0.08mm centering wobble, rotational vibration, and eccentric tooth-side wear.
[Design Omission] The major-diameter centering fit is too loose, a design defect leading to poor centering and vibration.
1) Hold major-diameter centering clearance to H7/g6;
2) Inspect internal/external major-diameter dimensions;
3) On the first part, measure centering and vibration;
4) Hold grinding accuracy of major-diameter surfaces;
5) Keep moderate tooth-side clearance;
6) Refine centering-surface Ra;
7) Call out centering fit on the drawing;
8) Verify in rotation.
GB/T 1144-2001 Straight-sided splines — Dimensions, tolerances and inspection