E43-797 · Key-and-Spline Fit Error · A long spline with out-of-tolerance lead error gives axial tooth-side contact biased to one end, overload at that end under torque, and local tooth-side wear · ★★★
A long spline has an out-of-tolerance lead (tooth line) error; along the axis, tooth-side contact with the internal spline is biased to one end, one end's tooth sides overload under torque, local wear appears, and axial load sharing is uneven.
[Mechanism] Spline lead should be parallel to the axis; lead error biases axial tooth-side contact, overloads and wears one end, and makes load sharing uneven.
[Calculation] Lead error biases tooth-side contact to one end, shortens effective contact length, and raises stress and wear at that end.
[Design Omission] The spline lead error is out of tolerance, a design defect leading to axial eccentric loading.
1) Control spline lead error;
2) Hold hobbing/gashing machine accuracy to ensure lead;
3) On the first part, measure lead and contact;
4) Check tooth-side contact with bluing;
5) Carburize tooth surfaces for wear resistance;
6) Meet the centering-accuracy requirement;
7) Call out lead tolerance on the drawing;
8) Verify under torque transmission.
GB/T 3478.1-2008 Cylindrical involute splines