E43-817 · Key-and-Spline Fit Error · Spline end without lead chamfer causing misaligned and galling tooth ends on insertion, tooth-end burrs, forced insertion damaging tooth-flank mating surfaces · ★★★
The splined shaft end had no lead chamfer; when inserting the internal and external splines, the tooth ends did not align, they gall against each other, burrs formed, forcing insertion damaged the tooth-flank mating surfaces, and assembly was difficult.
[Mechanism] The spline end needs a lead chamfer for centering and insertion; without it, tooth ends gall, burr, and damage the mating surfaces.
[Calculation] Without a chamfer, the tooth ends are misaligned and gall at insertion start; tooth-end burrs and damaged mating surfaces compromise accuracy.
[Design Omission] No lead chamfer at the spline end; design omission leads to galling damage.
1) Add a lead chamfer (taper lead-in) at the spline end;
2) Check smooth insertion on the first article;
3) Deburr;
4) Use a reasonable chamfer angle;
5) Center during insertion;
6) Inspect tooth-end quality;
7) Specify end chamfer on the drawing;
8) Verify after assembly.
GB/T 3478.1-2008 Cylindrical involute splines