E43-820 · Key-and-Spline Fit Error · Internal spline actual space width acceptable but geometric error driving effective space width out of tolerance, interfering with external spline effective tooth thickness and binding insertion · ★★★★
The measured actual space width of the internal spline was within tolerance, but the effective space width (compensated for indexing and lead errors) came out too small; it interfered with the effective tooth thickness of the external spline, insertion bound, and forced assembly damaged the flanks.
[Mechanism] Spline insertion depends on the effective dimension (= actual dimension ± geometric error compensation); the actual size may be acceptable while geometric errors make the effective dimension interfere.
[Calculation] Indexing plus lead errors reduce the effective space width by 0.03mm relative to actual; it interferes with the external spline effective tooth thickness and binds.
[Design Omission] Only the actual dimension was controlled, not the effective dimension; design omission leads to insertion binding.
1) Inspect effective dimension with a composite Go gauge (Go gauge controls effective dimension);
2) Control actual dimension item-by-item with a No-Go gauge;
3) Control indexing and lead errors;
4) Verify insertion with the composite gauge on the first article;
5) Keep shaping/rolling process stable;
6) Meet the centering-accuracy requirement;
7) Specify composite inspection on the drawing;
8) Insertion verification.
GB/T 1144-2001 Straight-sided splines — Dimensions, tolerances and inspection