Large Common Normal Variation Causes Unsteady Running

E43-043 · Gear Drive Tolerance Errors · Planetary Gear · ★★

Problem Symptom

Common normal length variation 0.03 (allowable 0.012); speed fluctuated

Root Cause

[Common Normal] A common normal length variation of 0.03 reflects accumulated pitch error and degrades motion accuracy.
[Unsteady Running] The speed fluctuation made the load pulsate and the transmission ratio drift momentarily.
[Design Omission] The common normal variation should be ≤0.012 and the gear blank runout controlled, but no gear grinding was carried out.

Correct Solution

1) Control common normal variation to ≤0.012 to improve motion accuracy;
2) Control gear blank runout ≤0.01 to preserve the base circle;
3) Use finish rolling or grinding to improve motion accuracy and reduce noise;
4) Inspect the common normal 100% with a caliper gauge to guarantee conformance;
5) Inspect motion accuracy on the first piece for monitoring;
6) Test for speed fluctuation to verify smooth running;
7) Mark the matched pair and install them together to prevent mismatching;
8) Bring motion accuracy into the gear acceptance criteria.

Checklist

References

GB/T 10095.1-2008 Cylindrical Gears — Accuracy