Tooth Flank Direction Error Causes Uneven Loading and Tooth Breakage

E43-088 · Gear Drive Tolerance Errors · Cement Mill Gear · ★★★

Problem Symptom

Tooth flank direction error designed Fβ0.02 but actual 0.10; uneven loading broke a tooth once

Root Cause

[Large Fβ] The design Fβ0.02 was actually 0.10, and the skewed tooth flank shifted the contact.
[Uneven Loading] The large Fβ concentrated the load at the tooth end, shrinking the contact spot and breaking the tooth.
[Design Omission] The tooth flank tolerance should have been specified with the contact pattern checked, but no Fβ inspection was done.

Correct Solution

1) Reduce Fβ to 0.02;
2) Finish the tooth flanks accurately;
3) Require contact spot ≥50%;
4) Ensure housing hole parallelism;
5) Follow GB/T 10095;
6) Measure Fβ on the first piece;
7) Run the machine unloaded to break in the tooth flanks;
8) Re-grind out-of-specification gears.

Checklist

References

GB/T 10095.1-2008 Cylindrical Gear Accuracy