Rack Pitch Error Causing Positioning Offset

E43-844 · Gear-Drive Tolerance Error · A CNC pinion-and-rack drive's out-of-tolerance cumulative pitch error accumulated positioning error along the stroke to a 0.1mm end offset · ★★★

Problem Description

On a CNC machine's pinion-and-rack drive, the rack cumulative pitch error was out of tolerance; positioning error accumulated along the stroke, reaching a 0.1mm offset at the stroke end, leaving long-travel machined dimensions out of tolerance.

Root Cause

[Mechanism] Rack pitch sets the pinion-and-rack travel; cumulative pitch error accumulates travel error along the stroke, offsetting end positioning.
[Calculation] The cumulative pitch error builds along the length, offsetting end positioning by 0.1mm, beyond the long-travel positioning requirement.
[Design Omission] The rack cumulative pitch error was out of tolerance - a design defect leading to accumulated positioning offset.

Corrective Solution

1) Control rack pitch accuracy or choose a high-precision rack;
2) Match pitch when joining rack sections;
3) Apply CNC pitch compensation;
4) On first articles, measure full-stroke positioning;
5) Hold rack mounting datum accuracy;
6) Match pinion accuracy;
7) Call out pitch accuracy on the drawing;
8) Verify positioning.

Checklist

Reference

GB/T 10096-1988 Rack gears - Accuracy