E43-862 · Gear-Drive Tolerance Error · A multi-stage gearbox's per-stage center-distance errors left some stages with wrong backlash, locally binding or large backlash error in the chain · ★★★
A multi-stage gearbox had per-stage bore center-distance errors: one stage was too small in center distance and bound with insufficient backlash, another too large with large backlash error, and the whole drive chain ran poorly.
[Mechanism] Each stage's center distance independently affects that stage's mesh; errors leave each stage's backlash / contact wrong.
[Calculation] Per-stage center-distance errors shift each stage's backlash, causing binding or backlash error and poor chain accuracy.
[Design Omission] The housing per-stage center distances were out of tolerance - a design defect leading to wrong per-stage backlash.
1) Jig-bore the housing per-stage center distances;
2) Check per-stage center distances by CMM;
3) On first articles, measure per-stage backlash;
4) Match tooth thickness per stage;
5) Machine the bore family in one setup;
6) Hold position tolerance to spec;
7) Call out per-stage center distances on the drawing;
8) Verify the drive chain.
GB/T 10095.1-2022 Cylindrical gears — System of accuracy