E43-090 · Seal and Clearance Fit Errors · Reactor Agitator Seal · ★★★
Clearance between the rotating ring and the shaft was 0.05 by design but 0.20 in practice; medium seeped out along the shaft
[Large Clearance] The design clearance was 0.05 but 0.20 was used by mistake because the shaft diameter was undersize.
[Leakage] The large clearance let the medium seep out along the gap between the shaft and the rotating ring.
[Design Omission] The clearance should be 0.05 with a throttling ring added, but no clearance inspection was done.
1) Set the clearance to 0.05;
2) Take the shaft diameter at the upper limit;
3) Add a throttling sleeve;
4) Verify the end-face specific pressure;
5) Follow GB/T 6556;
6) Inspect the clearance on the first piece;
7) Carry out a leakage test;
8) Replace out-of-specification parts.
GB/T 6556-2012 Mechanical Seals