E43-092 · Seal and Clearance Fit Errors · Steam Turbine Labyrinth Seal · ★★

Problem Symptom

Labyrinth clearance designed 0.30 but 0.80; steam bypassed and efficiency dropped 3%

Root Cause

[Large Clearance] The design was 0.30 but 0.80 was used because of off-position turning.
[Steam Bypass] The large clearance increased the leakage flow Q∝δ³, so efficiency fell.
[Design Omission] The clearance should be 0.30 with the turning controlled, but no clearance inspection was done.

Correct Solution

1) Set the clearance to 0.30;
2) Control the turning accuracy carefully;
3) Verify from Q∝δ³;
4) Specify the tooth tip thickness;
5) Follow GB/T 1801;
6) Inspect the clearance on the first piece;
7) Carry out an efficiency test;
8) Weld repair and re-turn out-of-specification parts.