E43-884 · Seal-and-Clearance Error · A high-pressure pump seal's rotating face flatness designed 0.9μm (three bands) but measured 3.5μm (seven bands), leaving local non-contact and film loss · ★★★★
A high-pressure centrifugal-pump seal, the rotating face was under-lapped and flatness measured 3.5μm (~seven light bands) over the 0.9μm design; the face locally warped open and medium leaked through the warp gap.
[Mechanism] The seal faces seal by high-flatness contact forming a stable μm film; out-of-tolerance flatness leaves local gaps far larger than the film, forming leak paths.
[Calculation] Face flatness reads in light bands; 1 band ≈0.29μm; design 0.9μm (≤3 bands) vs measured 3.5μm (~12 bands), local gaps of several μm exceed the 1~3μm film.
[Design Omission] The lapping step was not inspected and optical-flat bands were not checked - a design defect leading to out-of-tolerance flatness and face leakage.
1) Lap seal faces to flatness ≤0.9μm (≤3 bands) to hold contact;
2) Check light bands with an optical flat and file it, quantified;
3) Hold face roughness Ra≤0.1 (mirror) to reduce film disturbance;
4) Recheck flatness after assembly (assembly distortion);
5) Control the process to GB/T 6556 face flatness;
6) Hydrostatic-test first parts with no face leak;
7) Mark flatness light bands and lapping requirements on the drawing;
8) Re-lap out-of-tolerance faces to acceptable bands.
GB/T 6556-2012 Mechanical seals — Technical specifications