E43-895 · Seal and Clearance Fit Error · A hydraulic-cylinder Y-ring lip-to-bore fit designed 0 clearance / 0.3 interference measured 0.2 clearance (lip OD too small), so the lip does not bed at low pressure and leaks back · ★★★
A hydraulic-cylinder Y-ring lip should have 0.3 interference against the bore but actually had 0.2 clearance (lip OD too small); at low pressure the lip cannot self-seal into contact, and oil leaks back past the lip.
[Mechanism] A Y-ring self-seals by the initial interference of its lip against the mating surface; at low pressure, with no oil pressure to flare the lip, bedding relies entirely on the interference, so when interference becomes clearance the lip does not bed and it leaks.
[Calculation] Lip interference = lip OD − bore ID; designed +0.3, measured −0.2 (lip OD 0.5 too small); at low pressure the lip contact pressure is zero, and it leaks as soon as it moves.
[Design Omission] Lip OD was taken at the lower deviation and bore ID at the upper deviation, stacked — a design defect turning interference into clearance and causing low-pressure reverse leakage.
1) Control lip OD per GB/T 10708, holding lip interference 0.2~0.4;
2) Size interference = lip OD − bore ID, quantitatively;
3) On first articles, measure lip OD and bore ID as a matched pair;
4) Hold bore ID tolerance at H8, upper deviation;
5) Inspect incoming lip-material hardness and recovery;
6) On first articles, hold at low pressure 0.5MPa with no seepage, to verify;
7) Call out lip interference and bore tolerance on the drawing;
8) If interference is insufficient, switch to a larger lip-size ring.
GB/T 10708.1-2000 Rubber sealing rings for reciprocating motion — Structural dimension series