E43-901 · Seal and Clearance Fit Error · A pump mechanical-seal flush restrictor designed 3 measured 0.5 (machined too small), leaving too little flush flow, poor face heat removal, film vaporization and face damage · ★★★
A centrifugal-pump mechanical-seal flush system had a restrictor orifice measured at 0.5, far below the designed 3; flush flow is far too low, frictional heat at the faces cannot be carried away, the face liquid film vaporizes, and hot-spot damage appears on the rotating face.
[Mechanism] The seal faces rely on flush liquid to carry away frictional heat and maintain the liquid film; the orifice sets the flow, and too small an orifice leaves too little flow and a face temperature rise that vaporizes the film.
[Calculation] Flush flow Q ∝ orifice² √Δp; cutting the orifice from 3 to 0.5 (1/6) drops flow by about 1/36, and the face temperature rise from heat balance surges past the vaporization point.
[Design Omission] The restrictor orifice was machined too small without sizing the heat-removal flow — a design defect leading to insufficient flow and face vaporization damage.
1) Size the flush restrictor from the heat-removal flow and restore about 3 to keep flow;
2) Size the orifice from Q ∝ orifice² √Δp, quantitatively;
3) On first articles, check the orifice with a pin gauge to prevent undersize;
4) Fit a filter in the flush line to prevent clogging and keep it open;
5) Set the required flush amount from face heat balance;
6) On first articles, run and measure face temperature rise ≤ specified, to verify;
7) Call out flush orifice and flow requirements on the drawing;
8) If the orifice is undersize, ream it to the design or replace the restrictor.
GB/T 6556-2012 Mechanical seals — Technical specifications