E43-903 · Seal and Clearance Fit Error · A compressor dry-gas seal rotor-to-stator film gap designed 3μm measured 12μm, leaving low film stiffness and face contact wear under disturbance · ★★★★
A centrifugal-compressor dry-gas seal had a gas-film clearance between the rotor and stator faces measured at about 12μm, above the designed 3μm; film stiffness is low, the faces go unstable and touch under disturbances, and the seal faces wear.
[Mechanism] A dry-gas seal floats the faces non-contacting on a hydrodynamic gas film generated by grooves on the rotating ring; the film clearance must be held at micron scale for stiffness, and too large a clearance leaves low stiffness and face contact under disturbance.
[Calculation] Film stiffness K ∝ 1/clearance³; growing the clearance from 3 to 12 (4×) drops stiffness by about 1/64, crash resistance collapses, and the faces easily touch and wear.
[Design Omission] Groove depth and face flatness were poorly controlled, leaving too large a gas-film clearance — a design defect leading to low stiffness and face wear.
1) Control groove depth and face flatness to dry-gas-seal requirements, holding the film at 3~5μm;
2) Size film stiffness from K ∝ 1/clearance³, quantitatively;
3) Hold face flatness ≤1 light band, mirror Ra;
4) Precision-machine the groove depth and inspect depth consistency;
5) Match spring contact pressure to opening force to control lift;
6) On first articles, measure film clearance and stiffness, to verify;
7) Call out groove depth and face flatness on the drawing;
8) If the clearance is too large, re-lap the faces and adjust groove depth.
GB/T 6556-2012 Mechanical seals — Technical specifications