E43-908 · Seal and Clearance Fit Error · A control-valve stem-to-packing-ID clearance designed 0.1 measured 0.4, so the packing does not grip the stem and reciprocation carries media out · ★★
A control-valve stem packing had a stem-to-packing-ID clearance measured at 0.4, above the designed 0.1; the packing does not grip the stem firmly, and as the stem reciprocates, media is carried out along the stem.
[Mechanism] Valve stem packing seals media by radial contact pressure on the stem; too large a stem-to-packing clearance leaves insufficient grip, and reciprocation breaks the sealing line and leaks out.
[Calculation] Packing grip pressure on the stem falls as clearance grows; raising the clearance from 0.1 to 0.4 leaves insufficient grip, the dynamic sealing pressure falls below media pressure, and reciprocation carries the leak out.
[Design Omission] Stem diameter was taken at the lower deviation and packing ID at the upper deviation — a design defect leading to excessive clearance and stem-side external leak.
1) Hold stem-to-packing-ID clearance 0.05~0.15 to preserve grip;
2) Hold stem diameter tolerance at h8, lower deviation;
3) On first articles, check packing ID and stem diameter as a matched pair;
4) Hold stem surface Ra0.4~0.8 to reduce reciprocating wear;
5) Size from the grip-pressure vs. clearance relation, quantitatively;
6) On first articles, run a reciprocating test with no leak at the stem, to verify;
7) Call out stem tolerance and packing clearance on the drawing;
8) If clearance is too large, fit matching packing or plate the stem.
GB/T 1801-2009 Limits and fits