E43-910 · Seal and Clearance Fit Error · A gear pump gear-face-to-side-plate clearance designed 0.03 measured 0.10, letting high-pressure chamber oil leak to the low-pressure chamber across the faces, dropping volumetric efficiency and pressure · ★★★
An external gear pump had an axial clearance between gear faces and side plate measured at 0.10, above the designed 0.03; high-pressure chamber oil leaks internally to the low-pressure chamber through the gear faces, volumetric efficiency drops, and output pressure fails to build.
[Mechanism] Gear pump face clearance is the main internal-leak path; high-pressure oil returns to the low-pressure chamber along the gear-face-to-plate gap, and too large a clearance raises the leakage with the cube and drops efficiency.
[Calculation] Face internal leakage Q ∝ clearance³ × Δp; growing the clearance from 0.03 to 0.10 (3.3×) raises leakage by about 37×, sharply dropping volumetric efficiency and pressure.
[Design Omission] Face clearance was taken at the upper deviation with no floating side-plate compensation — a design defect leading to excessive clearance and face internal leakage.
1) Hold gear face clearance 0.02~0.04 to cut internal leakage;
2) Use a floating side plate that automatically compensates face clearance at high pressure;
3) Size the clearance from Q ∝ clearance³ Δp, quantitatively;
4) Control side-plate and gear-face flatness and Ra;
5) Match gear width to pump-body bore depth;
6) On first articles, measure volumetric efficiency and rated pressure, to verify;
7) Call out face clearance and side-plate compensation on the drawing;
8) If clearance is too large, grind-fit the side plate or replace parts.
GB/T 1801-2009 Limits and fits