E43-913 · Seal and Clearance Fit Error · A rotary joint rotor/stator face gap designed to be closed by spring clamp actually had weak spring force, opening a 0.05 face gap through which high-pressure water leaks · ★★★
A high-pressure water rotary joint's rotor/stator face seal had insufficient spring clamp, opening a 0.05 gap between the faces; high-pressure water leaks out along the face gap and the joint drips.
[Mechanism] A rotary joint seals the rotating interface by spring-clamping lapped rotor/stator faces together; weak spring force lets water pressure pry the faces open and leak through the gap.
[Calculation] Face contact pressure = spring force / face area, and must exceed the water-pressure opening force on the face; weak spring force makes the net pressure negative, prying the faces open 0.05 and leaking.
[Design Omission] Spring clamp was not sized from water pressure and face flatness was poor — a design defect leading to a face gap and high-pressure water leak.
1) Size spring clamp from water pressure to keep net face contact pressure >0;
2) Size from face contact pressure − opening force, quantitatively;
3) Lap rotor/stator faces to flatness ≤2μm;
4) Select a wear-resistant face pair (silicon carbide on carbon) for wear resistance;
5) Inspect incoming spring force, holding the lower limit;
6) On first articles, run a high-pressure water test with no face seepage, to verify;
7) Call out spring force and face flatness on the drawing;
8) If spring force is weak, replace the spring or add shims to boost pressure.
GB/T 6556-2012 Mechanical seals — Technical specifications