E43-925 · Seal and Clearance Fit Error · An LN2 pump cryogenic rubber O-ring passed room-temperature compression but at low temperature the material shrinks and hardens, measured contact pressure goes to zero and it leaks in cryogenic service · ★★★
A liquid-nitrogen cryopump O-ring seal passed compression check at room temperature, but at cryogenic temperature the rubber shrinks and hardens, losing elasticity; measured sealing contact pressure goes to zero in service, and LN2 leaks along the seal.
[Mechanism] Cryogenic temperature makes rubber glass-transition shrinkage and hardening, losing elastic recovery; the contact pressure built at room-temperature compression goes to zero at low temperature from shrinkage and hardening, losing the seal.
[Calculation] Cryogenic shrinkage = α_cryo × dimension × ΔT; at LN2 −196℃ rubber shrinks markedly past the glass point, modulus surges, recovery tends to zero, and contact pressure goes to zero.
[Design Omission] The seal material was not selected for cryogenic service and cryogenic shrinkage was not accounted for — a design defect leading to low-temperature loss of elasticity and leak.
1) Select cryogenic seal materials (cryo-FKM / PTFE / metal) to keep low-temperature elasticity;
2) Size cryogenic shrinkage = α × dimension × ΔT, quantitatively;
3) Use a spring-energized seal to compensate cryogenic shrinkage;
4) Keep the material glass-transition temperature below the operating temperature;
5) Measure seal shrinkage and hardness at low temperature;
6) On first articles, run a cryogenic service test with no seepage, to verify;
7) Call out cryogenic material and glass-transition temperature on the drawing;
8) If material is unsuitable, switch to a cryogenic-specific seal.
GB/T 1801-2009 Limits and fits