E43-927 · Seal and Clearance Fit Error · A globe-valve plug-to-seat cone interference contact band designed width 1 measured discontinuous, so the valve does not shut tight and media leaks internally · ★★★
A globe-valve plug cone-to-seat cone fit had mismatched cone angles, making the sealing contact band discontinuous (designed continuous band width 1); on closure, local areas do not contact, media leaks internally through gaps, and the valve does not shut tight.
[Mechanism] The valve seat seals when plug and seat cones form a continuous contact band under closing force; a cone-angle mismatch leaves a discontinuous band and local gaps that leak internally.
[Calculation] Contact-band continuity depends on the difference between the two cone angles; a mismatch makes contact start at one circumferential point, and closing force is too weak to plastically fill it, leaving a discontinuous gap and internal leak.
[Design Omission] Plug and seat cone angles were inconsistent and the seal faces were not lapped together — a design defect leading to discontinuous contact and valve internal leak.
1) Match plug and seat cone angles and lap them together to keep a continuous contact band;
2) Check the contact band by blue marking, continuous ≥360°, quantitatively;
3) On first articles, check cone angle and seal-face Ra;
4) Match seal-face hardness for micro-plastic bedding;
5) Size closing force to the sealing contact pressure, ensuring it is sufficient;
6) On first articles, close and pressure-test with no internal leak, to verify;
7) Call out matched cone angle and contact-band requirement on the drawing;
8) If contact is discontinuous, lap the seat or replace the plug.
GB/T 12235-2007 Steel globe valves and lift check valves for petroleum, petrochemical and related industries