E43-371 · Welded/Cast Forming Dimensional Error · A pipe flange with ø22 holes on a 600mm pitch circle, designed hole position ±0.5, measured 2.4 · ★★
Flange weld shrinkage misaligns the bolt holes by 2.4mm, so bolts cannot pass through.
[Mechanism] Circumferential weld shrinkage offsets the flange relative to the pipe axis, misaligning the bolt-hole group.
[Calculation] Hole-position shift Δ≈α·ΔT·L=11.5e-6×30×600≈0.2 (2.4mm measured with shrinkage), 4.8× the tolerance of 0.5.
[Design Omission] No welding-before-drilling or allowance — a design defect leading to hole misalignment.
1) Tack the flange, weld, then ream;
2) Match-drill the bolt holes after welding;
3) Use a fit-up fixture to control position;
4) Weld symmetrically to reduce shrinkage bias;
5) Control heat input;
6) Inspect with a hole-spacing gauge;
7) Trial-insert bolts to verify;
8) First-article hole position ≤0.5mm.
GB/T 9115-2010 Steel butt-welding pipe flanges