E43-377 · Welded/Cast Forming Dimensional Error · A truss node at coordinates (2000,1500), designed position ±1, measured displacement 4 · ★★
Truss weld shrinkage shifts node positions by 4mm, biasing overall dimensions.
[Mechanism] Member weld shrinkage shifts node coordinates, pushing truss geometry out of tolerance.
[Calculation] Node displacement Δ≈ΣΔL·cosθ=4×0.02×...≈4mm (multiple members accumulate), 4× the tolerance of 1.
[Design Omission] No shrinkage allowance or fixture — a design defect leading to node displacement error.
1) Use an assembly fixture to control node position;
2) Leave shrinkage allowance on members;
3) Symmetrical welding to reduce deviation;
4) Apply pre-anti-distortion before welding;
5) Control heat input;
6) Correct after welding;
7) Measure node coordinates with a total station;
8) Measure first-article position ≤1mm.
GB/T 50205-2020 Standard for acceptance of construction quality of steel structures