Knowledge Base › Tolerance and Fit Error Case › Steel-Column Weld Longitudinal Bow Causing Perpendicularity Error

Steel-Column Weld Longitudinal Bow Causing Perpendicularity Error

E43-382 · Welded/Cast Forming Dimensional Error · A steel column 6000mm tall, designed perpendicularity ≤H/1000, measured bow offset 8 · ★★

Problem Description

Weld side-bow of the steel column pushes perpendicularity 8mm out of tolerance, leaving it tilted on installation.

Root Cause

[Mechanism] One-sided weld shrinkage of the box column body produces a side bow, pushing perpendicularity out of tolerance.
[Calculation] Perpendicularity deviation Δ≈f=8mm (side bow), 1.3× the H/1000=6 limit.
[Design Omission] No symmetric welding or correction — a design defect leading to perpendicularity error.

Corrective Solution

1) Weld both webs symmetrically to control side-bow;
2) Apply an anti-distortion pre-bend;
3) Hydraulically straighten after welding;
4) Control heat input;
5) Add temporary bracing;
6) Stress-relieve after welding;
7) Measure perpendicularity with a theodolite;
8) Measure first-article perpendicularity ≤H/1000.

Checklist

Reference

GB/T 50205-2020 Standard for acceptance of construction quality of steel structures