MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › Steel Beam Welded Flange Buckling-Wave Error

Steel Beam Welded Flange Buckling-Wave Error

E43-393 · Welded/Cast Forming Dimensional Error · An H-beam flange 300mm wide, designed wave ≤1, measured post-weld wave 4 · ★★

Problem Description

After welding, the flange plate buckles in compression into a wave 4mm out of tolerance and distorted in appearance.

Root Cause

[Mechanism] Longitudinal weld shrinkage puts the flange plate in compression; buckling produces a wave.
[Calculation] Critical stress σ_cr≈3.6E(t/b)²=3.6×110000×(20/300)²≈176MPa (below the residual weld stress, causing the wave); wave height 4 exceeds the 1 limit.
[Design Omission] No stiffeners or segmented welding — a design defect leading to wave error.

Corrective Solution

1) Add longitudinal stiffeners to the flange;
2) Weld segmented skip passes with low heat input;
3) Flatten after welding;
4) Add temporary rigid bracing;
5) Control the welding sequence;
6) Stress-relieve after welding;
7) Measure the wave with a straight edge;
8) Measure first-article wave ≤1mm.

Checklist

Reference

GB/T 11263-2017 Hot-rolled H sections

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL