Welded Conduit Butt Coaxiality Error

E43-395 · Welded/Cast Forming Dimensional Error · A conduit ø80mm, designed coaxiality φ0.1, measured post-weld offset 1.2 · ★★

Problem Description

Fit-up misalignment of the conduit pushes coaxiality 1.2mm out of tolerance and raises flow resistance.

Root Cause

[Mechanism] When fitting the conduit the two tube axes are offset; after circumferential welding coaxiality is out of tolerance.
[Calculation] Coaxiality≈2e=2×0.6=1.2mm (offset e), 12× the tolerance of φ0.1.
[Design Omission] No fit-up fixture or concentricity calibration — a design defect leading to coaxiality error.

Corrective Solution

1) Use a fit-up fixture to control concentricity;
2) Position with an internal expansion ring;
3) Check offset ≤0.1 before tacking;
4) Weld symmetrically to prevent shift;
5) Control the gap;
6) Internal straightening after welding;
7) Check coaxiality with a mandrel;
8) Measure first-article coaxiality ≤φ0.1.

Checklist

Reference

GB/T 1184-1996 Shape and position tolerances - Undefined tolerances

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL