E46-105 · Assembly Sequence & Datum · Flange Cover · ★★
The four bolts of the flange cover were tightened one by one before the whole was leveled; the flange face warped, the gasket was pinched off-center and it leaked.
[Mechanism] Tightening before leveling makes the bolt preload uneven and distorts the flange.
[Calculation] The one-sided preload difference makes the flange warping exceed the gasket compression and causes leakage.
[Design gap] Symmetrical stepwise tightening with simultaneous leveling was not adopted.
① Symmetrical steps: tighten the bolts in a diagonal order in 2~3 increasing passes to keep the loading even
② Level as you tighten: check the flange face gap with a feeler gauge while tightening and keep the flatness ≤0.05mm
③ Control the torque: tighten to the design torque value with a torque wrench, avoiding over- and under-tightening
④ Apply locking: apply thread-locking compound or add spring washers as specified
⑤ Clean the sealing faces: before assembly clean the flange and sealing faces, free of scratches and foreign matter
⑥ In-process inspection: check the flange gap during tightening to detect warping early
⑦ Quality verification: confirm there is no leakage by an air or water pressure test
⑧ Standardize process: write symmetrical stepwise tightening into the assembly card, controlling at the source
GB/T 3098.1-2010 Mechanical properties of fasteners - Bolts, screws and studs