E46-134 · Assembly Sequence & Datum · Precision Guide Rail · ★★
A precision guide rail was mounted face-to-face on its datum, but chips left uncleaned underneath raised it locally by 0.15mm, putting the rail straightness out of tolerance.
[Mechanism] Foreign matter on the datum face raises the contact surface locally and destroys the flat datum.
[Calculation] Chips 0.15mm thick make the straightness error twice the tolerance.
[Design gap] Cleaning the datum face before assembly was not specified.
① Clean the datum face: before assembly clean the datum face thoroughly with solvent and a lint-free cloth, leaving no chips or oil
② Check the fit: use marking compound or a feeler gauge to check the fit and confirm there is no local gap
③ Remove burrs: clean off burrs and edges on the datum face to keep it flat
④ Clean environment: assemble at a clean station to prevent recontamination
⑤ Re-check straightness: after assembly measure the straightness to confirm it is ≤ the requirement
⑥ In-process inspection: check cleanliness before mating to detect foreign matter early
⑦ Quality verification: measure the straightness with a level or laser to confirm acceptance
⑧ Standardize process: write datum-face cleaning into the assembly process, controlling at the source
GB/T 1182-2018 Geometrical product specifications (GPS) - Geometrical tolerancing