E46-163 · Fastening & Anti-Loosening · Equipment base · ★★
Two bolt lengths were mixed on the same flange face; the long bolts were tightened fully home while the short ones were still loose, the flange was loaded unevenly, and the sealing face could not be pressed tight locally, causing leakage.
[Mechanism] Long and short bolts have different stiffness; at the same torque a short bolt elongates less and provides lower clamping force, causing uneven pressure distribution on the flange face.
[Calculation] Bolt stiffness k=F/δ; a shorter bolt has higher k, so at the same torque the elongation δ is smaller, the preload F is lower, and the local contact pressure is insufficient.
[Design gap] The bolt length specification for the same joint face was not unified.
① Unify the specification: use bolts of the same length and grade throughout the same flange face
② Check the list: verify bolt lengths item by item against the drawing when issuing materials to prevent mixing
③ Tighten in passes: snug and then final-tighten in a diagonal cross pattern so all bolts carry equal load
④ Check protrusion: after final tightening confirm all bolts protrude equally with no mismatch
⑤ Torque measurement: tighten with the same torque tool to ensure the same torque on one face
⑥ Check leakage: during pressure testing, focus on the leak points previously caused by mixed lengths
⑦ Consistency verification: confirm even flange compression by consistent bolt protrusion
⑧ Standardize process: write the requirement of same-specification bolts per face into the work card
GB/T 5782-2016 Hexagon head bolts