E46-177 · Fastening & Anti-Loosening · Pressure vessel flange · ★★★
When tightening bolts with a hydraulic tensioner, the pump pressure exceeded the set value; the bolt was overstretched into the plastic range, so after unloading the elongation did not recover, the preload ended up below design, and the bolt became thinner.
[Mechanism] The hydraulic tensioner stretches the bolt to a set elongation by oil pressure; overpressure pushes the elongation past yield and causes permanent deformation.
[Calculation] The stretching force F = oil pressure × piston area; overpressure makes F exceed the bolt's yield load, and residual elongation after unloading leaves the clamping force insufficient.
[Design gap] The pump pressure upper limit was not calibrated and the operator pressurized by feel.
① Calibrate the pump pressure: back-calculate the maximum pump pressure from the target elongation, fit a limiting valve, and prohibit overpressure
② Stepwise stretching: raise the pressure to the set value in two stages, holding and measuring the elongation at each stage
③ Measure elongation: measure the actual elongation with a dial gauge or ultrasonic device, and stop at the set value
④ Replace overpressurized parts: bolts already plastically elongated by overpressure are rejected and replaced
⑤ Calibrate equipment: calibrate the tensioner and pressure gauge periodically to ensure accurate readings
⑥ Two-person confirmation: have two people cross-check pressurizing and readings to avoid mistakes
⑦ Elongation verification: use the measured elongation to confirm operation within the elastic range
⑧ Standardize process: write the pump pressure upper limit and elongation control into a dedicated procedure
GB/T 1231-2006 High-strength large hexagon head bolts for steel structures