E46-184 · Fastening & Anti-Loosening · Vibrating conveyor · ★★
The vibrating conveyor's hanger rods were suspended with ordinary nuts; prolonged high-frequency vibration slowly loosened the nuts, the hanger rods sank, the machine body tilted, and it nearly came off the hook.
[Mechanism] The hanger rod is subjected to alternating tension and vibration; an ordinary nut relies only on friction for anti-loosening, and vibration makes the friction coefficient fluctuate so the nut turns loose.
[Calculation] When the vibration frequency approaches the nut's natural loosening frequency, loosening accelerates and obvious sagging appears within a few months.
[Design gap] No anti-loosening fasteners were used at the suspended load-bearing vibrating location.
① Use anti-loosening parts: replace the hanger rod nuts with all-metal lock nuts or add threadlocker
② Double nuts: use a thin and a thick nut jammed together for anti-loosening
③ Add locking: use a cotter pin or locking plate as a mechanical stop
④ Regular inspection: each shift, check the hanger rod nuts for sagging and re-tighten
⑤ Add marks: mark lines on the nut and hanger rod so misalignment is visible on inspection rounds
⑥ Load calculation: verify that the hanger rod and safety factor satisfy the vibration condition
⑦ Anti-loosening verification: confirm by re-tightening and marks that there is no continued loosening
⑧ Standardize design: note on the drawing that anti-loosening parts must be used at suspended vibrating locations
GB/T 6182-2014 Prevailing torque type all-metal hexagon nuts, style 2