E46-189 · Fastening & Anti-Loosening · Bracket connection · ★★
The bolted joint faces were not parallel, so the bolt was subjected to eccentric tensile load and bending; during operation it broke at the thread root and the bracket fell off.
[Mechanism] Non-parallel contact faces put the bolt under additional bending; at the thread root, where stress concentrates, the bending stress adds up and exceeds the strength.
[Calculation] The eccentricity e produces additional bending stress σb=Fe/W; superimposed on the tensile stress, the total stress exceeds the tensile strength and the bolt breaks.
[Design gap] The joint faces were not kept parallel; the bolt was used to force them together.
① Ensure parallelism: machine or grind the joint faces so the contact faces are parallel and fit with no gap
② Add a spherical washer: use a spherical washer for self-alignment to reduce the eccentric bending moment
③ Control tightening: avoid using excessive torque to forcibly pull non-parallel faces straight
④ Check the fit: after assembly, use a feeler gauge to check the joint faces for gaps
⑤ Add locating pins: at shear locations add pins to carry the transverse force so the bolts only take tension
⑥ Raise the grade: where eccentricity is unavoidable, use a higher bolt grade to increase the safety factor
⑦ Load verification: confirm by tight joint faces that the bolts are not subjected to bending
⑧ Standardize process: write the joint-face parallelism requirement into assembly inspection
GB/T 3098.1-2010 Mechanical properties of fasteners - Bolts, screws and studs