Knowledge Base › Process and Assembly Error Case Study › High-Strength Bolts Snug-Tightened but Not Final-Tightened

High-Strength Bolts Snug-Tightened but Not Final-Tightened

E46-200 · Fastening & Anti-Loosening · Roof truss · ★★★

Problem Description

High-strength bolt work stopped after the snug tightening while waiting for materials, and the subsequent final tightening was overlooked; the joint stayed at low preload for a long time and slipped in strong wind, deforming the truss.

Root Cause

[Mechanism] With only snug tightening, the preload of a high-strength bolt is just a fraction of the final tightening value; the slip resistance is far too low and the joint slides under load.
[Calculation] The snug-tightening preload is about 30%~50% of the final-tightening value, so the slip resistance is correspondingly insufficient and the joint slips under wind load.
[Design gap] Process handover was unclear, and the final-tightening state was not marked after snug tightening, leading to missed final tightening.

Corrective Solution

① Mark the final-tightened state: after snug tightening, draw a white line on the nut, and after final tightening add a crossing line; no crossing line means it was not finally tightened
② Process handover: treat snug tightening and final tightening as two separate operations with signed handover; no clarity, no handover
③ Full inspection: after final tightening, check the double-line markings bolt by bolt to confirm completion
④ Re-tighten: whenever a missed final tightening is found, immediately tighten it to the design torque
⑤ No skipping: final-tighten in numbering order without missing any bolt
⑥ Acceptance record: only when the joint's final-tightening completion rate is 100% may the next operation begin
⑦ Final-tightening verification: confirm by the double-line markings that all bolts are finally tightened
⑧ Standardize process: write the snug/final tightening markings and handover into the construction specification

Checklist

Reference

GB/T 1231-2006 High-strength large hexagon head bolts for steel structures