E46-202 · Bonding & Sealing · Plastic gear · ★★
A plastic gear was bonded to a metal shaft with instant adhesive (cyanoacrylate); after a few hours of operation it came apart under the transmitted torque, with the adhesive layer showing brittle fracture.
[Mechanism] Instant adhesive is highly brittle with poor impact and peel resistance; the transmitted torque subjects the interface to peeling and impact, causing brittle fracture.
[Calculation] The peel strength of instant adhesive is under 1MPa, far short of what torque transmission through the gear requires.
[Design gap] The adhesive was not selected by load type; quick-setting adhesive was used instead of a structural load-bearing adhesive.
① Select the adhesive by load: for load-bearing bonds that transmit torque, switch to epoxy or acrylic structural adhesive
② Toughening modification: use a rubber-toughened structural adhesive to improve impact and peel resistance
③ Increase the bond area: lengthen the socket joint or design a combined socket-and-bonded connection
④ Surface activation: use a dedicated primer on the plastic bonded surface to improve adhesion
⑤ Cure fully: cure the structural adhesive fully at the temperature, humidity, and environment stated in the instructions
⑥ Static-load test: after bonding, perform a torque static-load test to verify the load capacity
⑦ Bond verification: confirm by a torque test that the joint does not come apart during operation
⑧ Standardize process: write the adhesive type and process into the drawing to control from the source
GB/T 7124-2008 Adhesives - Determination of tensile shear strength (rigid material to rigid material)