E46-247 · Bonding and Sealing · Mechanical Seal · ★★★
The pump mechanical-seal gland bolts were tightened unevenly; the skewed gland made the seal-face contact pressure high on one side and low on the other, so the low side leaked and the graphite ring on the high side cracked.
[Mechanism] A skewed gland makes the seal-face pressure uneven: the low side leaks from insufficient pressure, and the high side cracks the ring from overpressure.
[Calculation] The torque difference puts the face parallelism out of tolerance, leaving the local contact pressure insufficient.
[Design gap] The gland bolts were not tightened crosswise in even, staged increments.
① Crosswise tightening: tighten the gland bolts diagonally, crosswise, in stages
② Even torque: keep the torque the same on all bolts
③ Check parallelism: measure the gland parallelism while tightening
④ Control the contact pressure: bring the face pressure to an even design value
⑤ Bar over: after assembly, turn the shaft by hand to check for uneven wear
⑥ Trial run: run in trial to check for leakage and temperature rise
⑦ Seal verification: confirm no leakage in the trial run
⑧ Standardize process: write the tightening sequence and torque into the procedure
GB/T 6556 Mechanical seals - Types and parameters