E46-362 · Surface Treatment & Coating · Equipment enclosure · ★★
After the topcoat was sprayed the lower coat wrinkled and lifted; an alkyd topcoat was applied over nitrocellulose lacquer, and the strong solvent swelled the lower coat.
[Mechanism] The topcoat's strong solvent dissolves the uncured lower coat, causing lifting and wrinkling.
[Calculation] Lifting occurs when the topcoat solvent's dissolving power exceeds the lower coat's solvent resistance; a wrong match causes damage.
[Design gap] The topcoat system was not chosen according to coating compatibility.
① Define the system: choose a compatible topcoat based on the lower coat and avoid strong solvents
② Test compatibility: run a compatibility test on a sample to confirm no lifting
③ Control the interval: let the lower coat cure fully before topcoating to keep it stable
④ Lifting check: check a test panel for lifting and detect problems early
⑤ Re-coat: sand and redo the system on lifted parts to restore intercoat bonding
⑥ Control solvent: choose a weak-solvent topcoat to reduce swelling
⑦ Compatibility verification: confirm intercoat stability by adhesion testing, confirmed by data
⑧ Standardize process: write the compatibility table into the painting process, controlling at the source
GB/T 30790.1-2014 Paints and varnishes - Protective coating systems