MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Process and Assembly Error Case Study › Handling Before Full Cure After Coating, Sticking Damage

Handling Before Full Cure After Coating, Sticking Damage

E46-390 · Surface Treatment & Coating · Coated part · ★

Problem Description

The coating was only surface-dry, not fully cured, and got pressed and stuck off; handling too early while the film was soft damaged the surface.

Root Cause

[Mechanism] Handling before full cure leaves the film soft, and it sticks and peels under pressure.
[Calculation] Epoxy needs 7 days to fully cure at 25℃; handling too early damages it.
[Design gap] Handling before full cure was not prohibited.

Corrective Solution

① Control full cure: prohibit handling before full cure to protect the film
② Control the environment: use a suitable temperature to speed curing
③ Stand upright: stand parts upright to reduce contact and prevent sticking
④ Full-cure check: finger-touch test for hardness to detect problems early
⑤ Re-coat: sand and re-coat sticking-damaged parts to restore the surface
⑥ Separate: put spacers between parts to prevent contact sticking
⑦ Full-cure verification: confirm adequate cure by hardness, confirmed by data
⑧ Standardize process: write the handling prohibition into post-coating, controlling at the source

Checklist

Reference

GB/T 30790.1-2014 Paints and varnishes - Protective coating systems

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL