E46-425 · Commissioning & Run-In · Pressure vessel system · ★★★
During the system trial run the safety valve had not been calibrated to its set pressure; when the pressure exceeded the limit the valve did not open, and the piping flange gasket ruptured and leaked.
[Mechanism] A deviating safety-valve setting puts the opening pressure above the system's allowable value, so the protection is lost.
[Calculation] Once the opening pressure exceeds the design pressure by 10% the overpressure protection is lost.
[Design gap] The safety-valve setting was not calibrated before the trial run.
① Calibrate first: calibrate the safety-valve set pressure on a test bench before the trial run
② Lead seal: lead-seal the valve after calibration to prevent tampering
③ Opening test: raise the system pressure slowly and check the opening pressure and reseating
④ Select pressure: the set pressure must not exceed the vessel design pressure
⑤ Bypass: route through the bypass during calibration to stay safe
⑥ Record: record the set value and the valve tag number for traceability
⑦ Quality verification: confirm effective protection by the opening pressure, confirmed by data
⑧ Standardize process: write safety-valve calibration into the trial-run plan, controlling at the source
GB/T 12241-2005 Safety valves - General requirements