Post-Weld Distortion Not Included in the Dimension Chain

E46-466 · Dimension Chain & Tolerance Coordination · Welded member · ★★

Problem Description

A welded member was designed with a span of 1500±1 mm, but post-weld bending distortion measured 1503 mm with side bend, exceeding tolerance by 2 mm and preventing assembly.

Root Cause

[Mechanism] Unequal weld shrinkage produces bending distortion and changes the connecting dimension.
[Calculation] Accumulated angular distortion side bend f=ΣθL=2 mm.
[Design gap] Post-weld distortion was not predicted and no reverse distortion was preset.

Corrective Solution

① Predict: predict the distortion from the welding sequence, controlling at the source
② Preset: preset a reverse distortion at blanking, confirmed by data
③ Balanced welding: use symmetric skip welding to reduce side bend, detecting problems early
④ Fixture: control the shape with fixtures, preventing out-of-tolerance
⑤ Straighten: straighten after welding to tolerance, ensuring the span
⑥ Verify distance: measured span 1500±1 mm, correcting early
⑦ Quality verification: confirm assembleability by measured span, confirmed by data
⑧ Standardize process: write reverse distortion into the welding process, controlling at the source

Checklist

Reference

GB/T 19866-2005 Welding procedure specification