E46-474 · Dimension Chain & Tolerance Coordination · Cast housing · ★★
A cast bearing housing bore was designed as φ100H7, but accumulated draft angle and wall-thickness variation measured φ100.18, exceeding tolerance by 0.18 mm, giving a loose, shaky fit.
[Mechanism] The draft angle makes the bore large at the mouth and small at the bottom, and wall-thickness variation adds unevenness, so the fit dimension drifts.
[Calculation] A 1° draft angle enlarges the large end of the bore by +0.15, plus 0.03 wall-thickness variation.
[Design gap] The effect of casting draft on the fit bore was ignored, and no finish machining was done after casting.
① Leave allowance: leave stock in the cast bore and bore it to size after casting, controlling at the source
② Mark draft: specify the draft angle on the drawing and note it is a non-fit surface, confirmed by data
③ Even wall: optimize wall thickness to reduce distortion, detecting problems early
④ Measure bore: measure the bore diameter after casting, preventing looseness
⑤ Fine boring: fine-bore the fit bore after casting to hold H7, ensuring tightness
⑥ Verify fit: measured interference or clearance passes, correcting early
⑦ Quality verification: confirm the fit by measured bore diameter, confirmed by data
⑧ Standardize process: write cast-bore finish machining into the process, controlling at the source
GB/T 6414-2017 Castings - Dimensional tolerances