E46-483 · Dimension Chain & Tolerance Coordination · Precision part · ★★
The part's dimension chain was designed to machining tolerances without accounting for measurement error; parts that measured acceptable were 0.04mm out of tolerance after assembly, giving a tight fit.
[Mechanism] Gauge error and measurement uncertainty were not included, shifting the accept/reject judgment.
[Calculation] Measurement uncertainty u=0.02 and manufacturing tolerance 0.03 leave only 0.01 actually usable.
[Design gap] No margin was left for measurement tolerance.
① Account for measurement: include measurement uncertainty in the dimension chain, controlling at the source
② Leave margin: leave a measurement margin in the design tolerance, confirmed by data
③ Choose gauges: select a gauge accurate enough with u≤1/3 of the tolerance, detecting problems early
④ Measurement method: unify the measurement datum and method, preventing bias
⑤ Re-measure: re-check critical dimensions on a CMM, ensuring accuracy
⑥ Verify the dimension: the measured value sits mid-band within the acceptance zone, correcting early
⑦ Quality verification: confirm the assembly is not tight from the measurements, confirmed by data
⑧ Standardize process: write the measurement requirements into the inspection card, controlling at the source
GB/T 3177-2009 Geometrical product specifications (GPS) - Inspection of plain workpiece sizes