E46-495 · Dimension Chain & Tolerance Coordination · Reducer · ★★
The coaxiality of the two bearing housing bores was designed as φ0.02, but the accumulated error in the housing measured φ0.07, out of tolerance, causing excessive bearing temperature rise.
[Mechanism] The coaxiality error between the two bores imposes an additional bending moment on the bearing, causing friction and heat.
[Calculation] An eccentricity of 0.07 increases the additional load, pushing the temperature rise beyond the limit.
[Design gap] The two bores were not finish-bored from one face with two pins.
① Mark coaxiality: specify coaxiality φ0.02 for the two bores, controlling at the source
② Bore together: finish-bore in one operation from one face with two pins, confirmed by data
③ Measure coaxiality: measure coaxiality with a CMM, detecting problems early
④ Rework the bore: finish the out-of-tolerance bore to preserve coaxiality, preventing high temperature
⑤ Verify temperature: run in and measure the temperature rise ≤25K, ensuring normal operation
⑥ Verify coaxiality: measure coaxiality ≤0.02, correcting early
⑦ Quality verification: confirm low temperature from the measured coaxiality, confirmed by data
⑧ Standardize process: write the line-boring operation into the process, controlling at the source
GB/T 307.3-2017 Rolling bearings — General technical specifications