Abnormal bearing overheating is usually caused by a combination of the following factors: (1) improper lubrication — the grease fill is excessive (it should only fill 1/3 to 1/2 of the free cavity) or insufficient, the grease grade is wrong, or it has aged and caked; (2) mounting errors — misalignment of the inner and outer rings, or excessive face-runout of the shaft shoulder / housing bore causing uneven raceway loading; (3) an overly tight fit — excessive interference between the inner ring and the shaft reduces the clearance, even producing negative clearance; (4) overloading or eccentric loading that sharply raises the contact stress; (5) seal friction (contact seals churning oil at high speed); (6) contaminant particles entering the raceway and causing abrasive wear. Troubleshooting order: first feel the temperature rise and listen for abnormal noise, then check the grease quantity and grade, strip and inspect the clearance and raceway marks, and re-measure the form and position tolerances of the shaft and housing. As a rule of thumb, a temperature rise above 40 C deserves attention, and above 80 K the bearing must be stopped and repaired. For related dimensional parameters see bearing table tb-04, for life verification see calc-12, and for selection principles see g-01. (Note: bearing life is approximately inversely proportional to the cube of the load, L proportional to 1/P^3; a 25% load increase roughly halves the life, so reducing the load is more effective than raising the precision grade. After mounting, run the bearing unloaded for 30 min and confirm the temperature is normal before applying load; in high-temperature environments select C3/C4 clearance and switch to high-temperature grease (lithium-base grease upper limit about 120 C, polyurea grease about 160 C). Axial location and clearance re-measurement follow the assembly specification.)