L10 is the life reached at 90% reliability (revolutions or hours); it is a statistical value, not a guaranteed one. In application note: (1) the result is only a statistical mean; in practice it may fail early or exceed its rating; (2) if 99% or higher reliability is required, use the life correction factor a1 (99% is about 0.21 x L10, 95% about 0.62 x L10); (3) contamination and poor lubrication make the actual life far below the calculation, so multiply by the a23 service factor (clean 1.0, general 0.5, contaminated 0.2); (4) where multiple bearings carry the same load in the same direction, take the shortest life; (5) L10h = L10 x 10^6 / (60 n). It is recommended to design with a 2 to 3 times margin over the calculated value, and add an extra reliability factor for critical equipment. For equivalent load calculation see calc-12; for dimensions and rated loads see tb-04. (Note: bearing life is approximately inversely proportional to the cube of the load, L proportional to 1/P^3; a 25% load increase roughly halves the life, so reducing the load is more effective than raising the precision grade. After mounting, run the bearing unloaded for 30 min and confirm the temperature is normal before applying load; in high-temperature environments select C3/C4 clearance and switch to high-temperature grease (lithium-base grease upper limit about 120 C, polyurea grease about 160 C). Axial location and clearance re-measurement follow the assembly specification.)