Replacement criteria: (1) vibration severity exceeds the ISO 10816 level for the application (e.g. 4.5 mm/s alarm for a normal motor); (2) temperature persistently exceeds the temperature-rise limit; (3) grease turns black and contains metal debris; (4) pitting / spalling pits, cracks or cage breakage appear on the raceway / rolling elements; (5) noise shows obvious periodic characteristic frequencies. Remaining-life assessment uses condition monitoring: periodically measure the vibration spectrum (watch the BPFO/BSF/BPFI/FTF amplitude trends), check grease condition and record temperature rise. When the pitting area exceeds 5% of the raceway or the depth exceeds 0.3 mm, replacement is recommended. It is advised to keep an operating-hours log and put the bearing under key monitoring once it reaches half of L10h. For life and load see calc-12 and tb-04. (Note: in the field you can compare the same model of bearing with an infrared thermometer; a temperature difference above 15 C is judged abnormal. The grease replacement interval is generally 2000 to 4000 operating hours or one year; the grease dropping point should be 20 to 30 C above the operating temperature. Rolling-bearing vibration velocity RMS per ISO 10816 is 2.8 mm/s for caution and 4.5 mm/s for alarm on a normal motor. Seal and lubrication matching is covered in the sealing FAQ.)