Push force F = p x A minus friction, with A = pi D^2 / 4 (blind end); pull force A = pi (D^2 - d^2) / 4 (rod end, d is the piston-rod diameter). Design: (1) set the cylinder bore D by the load, with 1.2 to 1.5 times safety; (2) set the piston-rod diameter d by speed ratio and stability (slenderness over 10 needs Euler buckling verification); (3) add a cushion at stroke end (fixed / adjustable) to prevent impact; (4) select the seal by pressure and speed (see sealing FAQ); (5) match the mounting type (clevis / trunnion / flange) to the force; (6) minimum guide length to prevent binding. Common pressure grades are 16 / 21 / 25 MPa. For calculation and verification see g-01; for seal selection see faq-25. (Note: the hydraulic-cylinder piston-rod diameter is set by speed ratio (blind/rod-end area ratio 1.3 to 2) and stability; slenderness over 10 needs Euler buckling verification. The accumulator charge pressure is 0.8 to 0.9 times the system minimum working pressure. On commissioning, bleed air by jogging first, then raise pressure step by step; oil temperature is best controlled at 40 to 60 C.)