Contamination is the primary cause of hydraulic failure (over 70%). Control: (1) filter new oil to the target cleanliness (servo NAS 6 to 7, general NAS 9 to 10); (2) add an air breather filter to the tank and use a filter cart for filling; (3) install three-stage filtration: suction (80 to 100 mesh), high-pressure (10 to 25 micrometer), return (10 to 20 micrometer); (4) periodically sample and test particle count / water / viscosity; (5) dust-proof maintenance, no open tanks, clean tools; (6) prevent water (water emulsifies the oil and disables additives). Targets: mobile machinery ISO 19/17/14, machine tools ISO 16/14/11. For maintenance see g-01. (Note: the hydraulic-cylinder piston-rod diameter is set by speed ratio (blind/rod-end area ratio 1.3 to 2) and stability; slenderness over 10 needs Euler buckling verification. The accumulator charge pressure is 0.8 to 0.9 times the system minimum working pressure. On commissioning, bleed air by jogging first, then raise pressure step by step; oil temperature is best controlled at 40 to 60 C.)